Atlona AT HDVS RX V2 User Manual

Page 11

Advertising
background image

11

Note:
1. Each command and feedback is terminated with a carriage return.

2. Spaces aren’t allowed except in projector display on/off command strings.
3. AT-HDVS-RX RS-232 port settings:

115200 bps, 8 bit data length, No parity bit, 1 bit stop-bit, No flow control.

4. Feedback for a command repeats the original command.

5. If a command fails or is aborted, the feedback will be “COMMAND FAIL”.
6. Some commands support query function by parameter [?]

Example: To get projector’s display on command -> WP_DisplayOn[?]$

To get input status -> WP_Input[?]$

Commands cont.

WP_AutoDispOn[a]$

[a] ? , On , Off

Set auto [Dispaly On] enable/disable

WP_AutoDispOff[a]$

[a] ? , On , Off

Set auto [Dispaly Off] enable/disable

WP_HdcpInput[a]$

[a] ? , HDCP , NotHDCP, Auto

HDCP input mode

WP_VgaAuto[a]$

[a] Go

Run VGA source auto-adjust

WP_VgaClock[a]$

[a] ? , Normal , Inverse

Set VGA ADC clock polarity

WP_Info[a]$

[a] ?

Get RX firmware version

WP_InfoTx[a]$

[a] ?

Get TX / TX-WP firmware version

WP_Output[a]$

[a] ? , 0 , 1 , 2 ... (map osd menu Output list)

Select output resolution

WP_OverscanEn[a]$

[a] ? , Yes , No

Set overscan enable/disable

WP_OverscanH[a]$

[a] ? , 0 ~ 50

Set overscan H size (%)

WP_OverscanV[a]$

[a] ? , 0 ~ 50

Set overscan V size (%)

WP_AudioEn[a]$

[a] ? , On , Off

Set audio out On/Off

WP_AudioHdmi[a]$

[a] ? , On , Off

Set hdmi audio out On/Off

WP_AudioLR[a]$

[a] ? , On , Off

Set analog L/R audio out On/Off

WP_SystemRst[a]$

[a] Go

Run system reset

WP_PictureBri[a]$

[a] ? , + , - , 0 ~ 100

Set picture brightness

WP_PictureCon[a]$

[a] ? , + , - , 0 ~ 100

Set picture contrast

WP_PictureSat[a]$

[a] ? , + , - , 0 ~ 100

Set picture saturation

WP_PictureHue[a]$

[a] ? , + , - , 0 ~ 100

Set picture hue

WP_PictureSha[a]$

[a] ? , + , - , 0 ~ 100

Set picture sharpness

WP_PictureRst[a]$

[a] Go

Run picture reset

WP_ProjSW[a]$

[a] ? , 0 , 5 , 10 , ~ 300

WP_Standby[a]$

[a] ? , 0 ~ 10

Standby timer in minute

]$

Abort command, Feedback is
COMMAND FAIL

atlona.com

Toll free: 1-877-536-3976

Local: 1-408-962-0515

Advertising