1. Introduction

The CEL-160 represents a completely new

concept in instrumentation for the

measurement of sound and vibration. It

enhances the latest techniques to provide the

most convenient system for documenting

results.

An all-electronic writing system is

employed and hence there are no moving

parts to limit the writing speed. In practice, the

CEL-160 can accurately write levels which

have time constants as short as 10 Ms and

print actual waveforms up to 10 kHz. The

complete system is microprocessor controlled

and is programmed to print its own

measurement graticule as it records; full trace

annotation is provided allowing the time axis to

be read directly without the need for complex

measurement and calculation based upon

chart length. Inputs may be AC or DC signals

and these may be recorded as either

waveforms or levels with the RMS detector

having its time constant selected as either

10 mS, 125 mS (F), 1 S (S) or 10 S and its

output in either linear or logarithmic units. The

software provides for operation with a wide

range of serial and real time frequency

analyzers with; in the former case, a

subroutine that optimises the 'bandwidth-time

constant' product and in the latter full

alphanumeric annotation of each band level.

CEL-160 Graphic Recorders are available

in two basic hardware configurations that allow

for increasing data storage and higher levels of

programming. In addition to the facilities

provided by the basic unit as described above

the 'Program Level 2' option has the capacity

to operate in an expanded trace mode when

making RMS recording or in a transient capture

mode when making waveform recordings. It

also has provision for one customer specified

program package a few of which could be:

calculation of reverbration times (RT

60

),

calculation of period L

eq

or estimation of

hearing protector attenuation.

The CEL-160 incorporates a full

specification sound level meter to IEC 651

Type 1 (BS 6959 Type 1, ANSI S1.4 Type 1 and

DIN 45 633) and it is only necessary to add a

CEL-2980 preamplifier, connecting cable and

transducer to be able to make direct

recordings.

2. Commissioning

2.1

Schedule of Parts

The description CEL-160 Graphic Recorder

complete refers to the following items and on

receipt, the instrument should be checked

against this schedule. Items supplied are

common to both versions.

CEL-160

Graphic Recorder

RS 591-231 Battery Pack (set of five alkaline

manganese C cells)

CEL-3730

Pack of nine rolls of chart paper

RS-1

Screwdriver

CEL-3843

Writing comb brush

060019

Handbook

CEL-3876

Rule

In addition to the standard items listed above,

there are a number of optional items and

although provision for some of these is made

in the standard transit pack they are only

provided if specifically requested. Such items

will be detailed separately on invoices and

advice notes. The most popular of these items

are as follows.

Accessories

CEL-3729

Ever Ready Carrying Case for

CEL-160

CEL-3731

Rechargeable Battery Pack

(NiCad)

CEL-3732

AC Adaptor and Battery Charger

CEL-2980

Preamplifier

CEL-186/2F Precision Measurement

Microphone

CEL-3686/2 Cable CEL-2980 to CEL-160 -

2 metres

CEL-2962

Windshield for CEL-186/2

CT-3

Tripod (accepts CEL-2980

Preamplifier)

CEL-3025

Vibration Adaption Kit

(comprises accelerometer and

mounting kit, connection

cable, passive integrator and

slide rule).

Ancillary Instruments

CEL-177

Precision Acoustic Calibrator

CEL-196

Automatic Third Octave

Analyser

CEL-3789

Ever Ready Case for CEL-196

(fits to CEL-3729)

Page 4 - CEL-160 Graphic Recorder

Advertising