followed by a C. (Operation of C key is actual

entry time, eg for 5.53 p.m. key 1753C). Start

up state 00H00M00S. The instrument also has

a 10 day elapsed day counter and this will

increment 1 day as the clock passes 24.00 but

it cannot be preset.

D Preset Scale Annotation

When the instrument is being used with the

integral sound level meter, the annotation on

the top of the paper is the main attenuator

setting whilst that at the bottom is the same

level minus the dynamic range setting. If it is

required to operate in the non SLM mode then

the FSD figure should be entered as a one or

two digit decade followed by D. The minimum

scale deflection will again, be calculated from

the dynamic range setting.

eg for 180 dB FSD key 180D. Start up state

SLM calibration.

E Frequency Analysis Trigger

Operation of this key will initiate the frequency

analysis program. Full details are given in

Section 6 of this manual.

F. Select Frequency Analyser Type

The control logic to operate the following

analysers is pre-programmed into the CEL-160,

however, non-standard packages are available

and if fitted to this unit details are given in

section 12 of this manual.

0 CEL-196 Automatic Third Octave 20 Hz- 20 kHz

1 Rion SA-59 Serial Third Octave 25 Hz-20 kHz
2 Rion SA-59 Serial Third Octave 2.5 Hz-2 kHz 3 Bruel

and Kjaer 1618 Serial Third Octave

4 Bruel and Kjaer 2215 Serial Octave
5 Bruel and Kjaer 1616 Third Octave 25 Hz-40 kHz
6 Bruel and Kjaer 1621 Continually Variable Narrow

Band 20 Hz-20 kHz

7 Bruel and Kjaer 1621 Continually Variable Narrow

Band 2 Hz-2 kHz

8 Rion SA-24 Real Time Third Octave 31.5 Hz-8 kHz
9 Rion SA-24 Real Time Third Octave 1 Hz-250 Hz

eg for Bruel and Kjaer 1616 key 5F. Start up

state 0F.

3.2

Connectors

All the input connections to the CEL-160 are

on the panel that is located on the right hand

side of the instrument. The functions of these

are as below and are shown in Fig 1.

PRE-AMP: This socket accepts the input from

the CEL-2980 preamplifier which should be

connected via the CEL-3686/2 cable. It may

also be used for direct AC inputs. Full details of

connections and loading conditions are given in

Figure 2. It must be noted that when direct AC

inputs are connected, the function of the main

range switch is different; reference should be

made to Section 4.3 for full details.

FILTER IN AND FILTER OUT: These are

primarily intended for the connection of

external frequency analysers such as the

CEL-196. The filter output connector is only in

circuit when the frequency weighting (LIN - A-

FILTER) is set to the filter position, however,

the filter input is always in circuit.

Figure 1: Connector locations and pin connections

Page 8 - CEL-160 Graphic Recorder