Malfunction/action, Maintenance, Disposal/recycling – CEJN Cable Reels User Manual

Page 8: Warranty, Spare parts

Advertising
background image

8

3.4 Freewheel action (SE reels only)

4. Malfunction/action

Make sure that the cable reel is connected to the mains.
Check that all fuses are intact. When the fuse is disabled, you
should make sure that both the cable and the connected tool
are intact. Disconnect the live device/tool from the cable reel
before you screw the old fuse into place or replace it with a
new one. If the fuse is intact, it is probably the heat-sensitive
overload protection which has turned off the power supply to
the cable reel.

Make sure that the connected tool is not overloading the cable
reel. Before you turn the power supply back on, the live de-
vice/tool must be disconnected from the cable reel. Once the
cable reel has cooled down, after about ¿ ve minutes, you can
press the reset button.

4.1 The connected tool does not start

1. Pull out the cable until the noise from the snap-in locking mechanism stops.

2. Release the cable for about 10-20 cm and secure with the PT screw supplied.

3. Pull out the cable. The snap-in locking mechanism is now deactivated.

PT

4.2 The connected tool suddenly switches off

and cannot be restarted

Check that all fuses are intact. If the fuse was disabled, you
should make sure that nothing is wrong with the tool or cable
reel (e.g. short circuit). Disconnect the live device/tool from the
cable reel before you screw the old fuse into place or replace it
with a new one. If the fuse is intact, it is probably the heat-sen-
sitive overload protection which has turned off the power sup-
ply to the cable reel. Make sure that the connected tool is not
overloading the cable reel.

Before you turn the power supply back on, the live device/tool
must be disconnected from the cable reel. Once the cable reel
has cooled down, after about ¿ ve minutes, you can press the
reset button.

4.3 The cable cannot be fully retracted

Make sure that the latch has released. Check that the stop ball has not been displaced. If necessary the spring tension must be adjusted. Follow the instructions
(section 3.3).

4.4 The problem cannot be resolved by following the steps above

Get a quali¿ ed technician to inspect the cable reel and the installation. Take the cable reel to your retailer for examination and inspection.

5. Maintenance

Carry out regular checks that there are no problems with the cable, housing or protective device. Any damage or defects must be repaired immediately. Only a quali¿ ed
technician may replace a cable or reel ¿ tted with a spring cassette. Only original spare parts must be used!

DANGER!!
Contact with live parts means there is a danger of death. Never open the cable reel when it is connected to the mains. The power supply must always be disconnected
before service or repairs.

6. Disposal/Recycling

IMPORTANT!
Help us to take care of the environment. When disposing of the cable reel, please do so in accordance with local environmental regulations.

7. Warranty

CEJN AB provides a two (2) year warranty from the date of manufacture. Contact your retailer concerning warranty enquiries.

8. Spare parts

For safety reasons, only original spare parts must be used. See the last page of this user manual for a list of spare parts or contact your retailer.