5. Operation

Once you have installed the EMS-2 and connected the power supply and data cable,
you can switch the plotter on.
Important

:

Before switching the device on please ensure that there are no objects on the
writing/plotting area which might prevent the writing arm from moving freely.

All settings and commands are entered using the control panel.

Control Panel

Switch device on/off

Open and close pen
station to insert/remove
plotter pen

Manual movement in
X and Y directions,
lower the plotter pen

Delete data
downloaded from PC

Pause or stop plotter
activity

ON/OFF buttons
The ON/OFF buttons are used to activate and deactivate the device. When the plotter
is switched on, the writing arm moves to the top right-hand corner of the labelling area
and auto calibration takes place. The green light comes on when the system is ready
for use and to receive data from the PC.

Clear buffer
If the EMS-2 contains data the yellow light will come on. You can delete this data by
pressing the 'Clear buffer' key.
To do this the system must be in stop mode (red light on).