Appendix A: Unit State String description

“Unit State String" - current status of all parameters of the unit (lenght 90 bytes):

byte 1

'i'

byte 2 - 5

'0335'

byte 6 - 9

UnitID (BCD)

byte 10-11

FW version

byte 12

STX ("/02")

byte 13-14

input state (HEX)

byte 15-16

output state (HEX)

byte 17-18

internal check state (HEX) 01-O.K.

byte 19-20

unit address (HEX)

byte 21-22

unit bank (HEX)

byte 23-24

long press time in 0.1sec (HEX)

byte 25-26

input filter in 0.01sec (HEX)

byte 27-28

paired relay to relay 1 (HEX) 00-no pair.

byte 29-30

input1 mode (HEX) "0-NoAction", "1-Coded", "2-Relay", "3-SystemOn",
"4-Run", "5-Direction", "6-DelayedOff", "7-DelayedOn", "8-RunDC", "9-Pulse"

byte 31-32

paired relay to relay 2 (HEX) 00-no pair.

byte 33-34

input2 mode (HEX) "0-NoAction", "1-Coded", "2-Relay", "3-SystemOn",
"4-Run", "5-Direction", "6-DelayedOff", "7-DelayedOn", "8-RunDC", "9-Pulse"

...............
byte 55-56

paired relay to relay 8 (HEX) 00-no pair.

byte 57-58

input8 mode (HEX) "0-NoAction", "1-Coded", "2-Relay", "3-SystemOn",
"4-Run", "5-Direction", "6-DelayedOff", "7-DelayedOn", "8-RunDC", "9-Pulse"

byte 59-62

relay1 timer value (HEX)

byte 53-66

relay2 timer value (HEX)

...............
byte 87-90

relay8 timer value (HEX)

Status string example:

"i0335000501\0200000100000504000100010001000100010001000100010005000500050005000500
0500050005"