30

ST/SV-3210 and ST/SV-3306

4.3.1

Database Modification Example

This section details the modification of an Operational Database
parameter. The following example increases the printing speed parameter
from 6 to 8 IPS on the ST-3210; however, using the same basic
procedure, any of the parameters can be changed regardless of the printer
model.

ΠIf on-line, press the PAUSE button to place the printer off-line.

Press and hold the F2 button until the On-Line Indicator is lit

(approximately six seconds) then release.

The printer will turn off the
On-Line Indicator and
print:

STOCK ID = 5

Ž

Press the F2 button three times (allow time for printing following

each button press), to arrive at the Print Speed parameter.

The printer will print:

PRINT SPEED = 6 IPS
PARSER MODE = DTPL
TICKET WIDTH = 189 (48 MM)

STOCK ID = 5

Press the F1 button two times (again, allow time for printing

following each button press), to arrive at the 8 IPS setting.

The printer will print:

PRINT SPEED = 8 IPS

PRINT SPEED = 7 IPS
PRINT SPEED = 6 IPS
PARSER MODE = DTPL

TICKET WIDTH = 189 (48 MM)
STOCK ID = 5

• To save the changes and exit the mode, press and hold the F2 button

until the On-Line Indicator is lit (approximately six seconds) then
release.

The parameter changes can be confirmed by printing a Configuration
Ticket; see Section 3.5.1.