The SLT Series system is a dual redundant digit al

infrared point of operation guarding device which will

provide a signal to stop the machine when there is entry

into the guarded area. The system uses invisible infrared

light to detect obstructions protruding through the

guarded area. The use of infrared light provides an

unobstructed view of the work area and also makes the

SLT Series system insensitive to almost all ambient light

conditions.
The dual redundant system basically incorporates two

microprocessors, four watchdog timers, and two

separate captive contact relays to assure fail-safe

operation. If either microprocessor detects a failure in

the system or the other microprocessor , the working

microprocessor can shut down the unit. The watchdog

timers assures that if the oscillator on either

microprocessor is not running correctly, they can shut

the system down. The special

force-guided contact

relays*

allow self-checking software to detect a faulty

relay and shut down the unit with the redundant relay .

The Diagnostics Display allows the user to better

understand the current condition of the light curtain. If a

fault is discovered by the light curtain, it will be displayed.

The display is also used when options like the Floating

Blank or Auto Blank are being used. A brief description

of each follows:

The

Floating Blank

option allows work pieces

(designated by dimensions) to move throughout

the guarded area without shutting the machine

down but entry into the protected area by the

operator will still provide a signal to stop the

machine. The Floating Blank option does not need

to be adjusted for various positions or die height

changes, only adjusted for the size of the work

piece. Up to three beams at a time are allowed

to be obstructed when the Floating Blank option

is in use.
The

Auto Blank

option allows work pieces or fixed

objects to penetrate the guarded area without

shutting the machine down. The size and location

of the object(s) is automatically programmed into

the computer with a turn of a key, so you do not

need to know the size of the object to program

the unit. Auto Blank must be reprogrammed when

there is a loss of power. Up to eight beams at a

time are allowed to be obstructed when the Auto

Blanking option is in use.

The SLT Series system operates from two pylons. Power

must be supplied separately to both pylons using

standard wiring procedures. The interface or stop circuit

interconnection is made from the Receiver Pylon.
The SLT Series system can only be used on p art

revolution or clutched machines which can be signaled

to stop at any part of their cycle by opening an electrical

circuit.

T

T

T

T

Theor

heor

heor

heor

heory of

y of

y of

y of

y of Oper

Oper

Oper

Oper

Opera

aa

aation

tion

tion

tion

tion

The SLT Series system is an infrared light curt ain

consisting of two pylons that talk to each other via an

infrared channel called the Sync Channel. The Receiver

Pylon transmits to the Emitter Pylon for the purpose of

synchronizing the two units eliminating the need for a

third box with a cable connecting the pylons together .

The status of the Sync Channel can be determined by

the Diagnostics Display on the Receiver Pylon which

will show flashing decimal points to indicate that the

Emitter Pylon is not firing.
The Receiver Pylon is the controller and the Emitter

Pylon is slaved to it by the Sync Channel. The internal

logic of the Receiver Pylon controls the scanning

function, the detection, the output control, and the

internal diagnostic functions.
When the two pylons are synchronized, the Emitter Pylon

begins to scan from the top down with its infrared

emitters called “data channels” or otherwise known as

infrared beams. The Emitter Pylon’s beams are scanned

many thousands of times a second and, each time a

beam is selected, its infrared emitter is pulsed. This

sequential scan of infrared pulses is picked up by the

Receiver Pylon which is synchronized to the scanning

Emitter Pylon and recorded. If a beam is blocked by an

obstruction, the control logic drops out the Output Relays

and turns on the RED indicator.
The Internal Diagnostic Logic runs at the same frequency

as the scan frequency so all operational components

and timings are checked many thousands of times a

second to insure Fail-Safe operation. The control logic

in this unit has no lock-up or failed mode except for hard

internal failures. No matter what conditions prevail, the

unit is trying to keep all systems operational.

* Force-Guided Contact Relays

are mechanically linked together

to force both poles to maintain the same position regardless of

whether the relay is energized or de-energized. This allows a

welded contact to be detected by monitoring the other pole.