Thor 2 mW CATV RF Over Fiber Tx 45-870 MHz User Manual

Page 12

Advertising
background image

12

Use degreaser or alcohol cotton to wash carefully, after finishing let the surfaces dry for

two to three minutes before reconnecting.

Cleaned optical active connector should be connected to optical power meter to measure

out optical power, to confirm that it has been properly cleaned.

When the cleaned optical active connector screwed back to adapter, care should be taken

to avoid damaging the connector with excessive force.

The fiber active connector should be cleaned in pairs. If optical power is on the low side

after cleaning, the connector on the other end of the fiber may need to be cleaned.

Use compressed air or degrease alcohol cotton to wash the adapter carefully. When using

compressed air, aim the muzzle at the tube of the adapter to clean off any dust. When

use degreasing alcohol cotton, wiping motion needs to be consistent, otherwise the
connector won’t be properly cleaned

Special notice:

a. In the process of cleaning the fiber optic connector, you should avoid direct exposure to

the eye, which will cause permanent damage!!!!

b. Use proper force to install the fiber optic active connector, or the ceramic tape in the

adaptor will lead to failure. Once the ceramic tape is broken, the output optical power will

decrease rapidly. If you turn the fiber optic active connector slightly, the output optical power

changes obviously.

c. Please operate the optical fiber under the condition of close the pump laser. Or the big

output power will lead to burn the joint of the output optical fiber, which will reduce the

output power.