Test conditions:

Test link path is formed of standard fiber and standard optical receiver. Under the condition of

prescriptive link loss, set 84 PAL-D test source TV channel signals at 750MHz, when optical

receiver input optical power being -1dBm, measure C/ CTB, C/ CSO, C/ N.

4.2 Technique Parameter Table

Item

Unit

Technique Parameter

Optical Power

mW

4

6

8

10

12

14

16

18

20

22

24

26

Optical Link Path Loss

dB

7

9

10

11

11.8

12.5

13

13.6

14

14.4

14.8

15.1

Optical Wave Length

Nm

1550±20

Type of Laser

DFB

Optical modulation mode

Direct Optical Intension modulation

Optical connector Type

FC/APC, SC/APC

Frequency Range

MHz

47-750/862

RF Input Level

dBuV

72-88

Flatness In Band

dB

±0.75

RF Input Impedance

Ω

75

Input Reflection Loss

dB

≥ 16(47-550MHz); ≥ 14(550-750/862MHz)

C/CSO

dB

≥ 60

C/CTB

dB

≥ 65

C/N

dB

≥ 51

AGC Control Range

dB

±5

MGC Control Range

dB

0-10

Power Voltage

V

AC 110V-250V(50Hz or 60Hz)

Power Consumption

W

30

Operation Temperature

0 -- 45

Store Temperature

-20 -- +65

Relative Humidity

%

Max 95% no condensation

Dimension

mm

483(L)×380(W)×44(H)

Optical Link Path C/N Parameter:

Optic

power

Optical Loss(dB)

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

4mW

53.8

52.8

51.8

51

50.1

49.2

48.2

6mW

53.0

52.0

51.0

50.1

49.1

48.1

8mW

52.8

51.9

51.0

50.1

49.2

48.2

10mW

52.9

51.9

51.0

50.1

49.1

48.2

12mW

52.7

51.8

50.8

49.9

49.0

48.0

14mW

52.4

51.5

50.5

49.5

48.6

47.8

Advertising