HDA800(V2) Serial Protocol, Version 1.3, 9/12/13

RS-232 / TCP/IP Port Hardware

TCP/IP settings used by the HDA800(V2)

Default IP Address:

DHCP

Port Number:

50005

Duplex:

Full

Speed:

10/100 Mbps

RS-232 Pinout and Baudrate Settings

The RS-232 port on the HDA800(V2) is the same format, and pinout, as a PC modem, and uses the
same type of cable as a standard serial modem would, which is a standard straight through cable. Do
not use a cable that is marked as a “Null Modem” cable.

The HDA800(V2) can also be used with USB to RS-232 conversion cables, these are all typically
straight through cables. (Be sure to install any drivers that come with the USB to RS-232 cable you are
using.)

The RS-232 port is a female type DE-9 connector (sometimes mistakenly referred to as a DB-9 con-
nector) with the following pinout:

Pin definitions

1 - No Connect

6 - No Connect

2 - TX

7 - No Connect

3 - RX

8 - No Connect

4 - No Connect

9 - No Connect

5 - GND

Port settings used by the HDA800(V2)

Baudrate:

19200

Data Bits:

8

Stop Bits:

1

Parity:

NONE

Timing information (unless specified otherwise by a command’s description)

Min character to character time:

0ms

Min line to line time:

0ms

Min time between commands:

0ms

Max time to respond to a request:

100ms



 