To "confirming the trunk connection, Led indications confirming the trunk connection – D-Link KX-TDA100 User Manual

Page 210

Advertising
background image

2.13 Starting the Hybrid IP-PBX

210

Installation Manual

2.

Plug the AC power cord into the Hybrid IP-PBX and an AC outlet, and turn on the Hybrid IP-PBX. The
RUN indicator will flash.

Note

For safety reasons, do not stretch, bend, or pinch the AC power cord.

3.

While the RUN indicator is flashing, return the System Initialise Switch to the "NORMAL" position.
Depending on the configuration, initialisation takes about 1 min to 3 min. If successfully executed, the
RUN indicator will stop flashing and be kept lit.

All data will be cleared, and the Hybrid IP-PBX as well as all optional service cards (except for the IP-GW
card) will be initialised to the default values. The DPTs should show the time as 01:00.
The data of the IP-GW card will not be initialised.

Notes

Use only the AC power cord included with the Hybrid IP-PBX for the PSU.

Use only the supplied AC power cord for the purpose of applying the EMC standard, if the Hybrid
IP-PBX is connected (Germany only).

LED Indications

Confirming the Trunk Connection

After initialisation, programme the Hybrid IP-PBX and establish trunk connection, and then use a PT to
confirm it.

Indication

Colour

Description

RUN

Green

PBX status indication

OFF: Power Off (includes normal reset)

ON: Power On and running (on-line)

Flashing (60 times per minute): Starting up

Flashing (120 times per minute): Starting up or resetting with:

the System Initialise Switch in "SYSTEM INITIALIZE"
position

the SD Memory Card not inserted

ALARM

Red

Alarm indication

OFF: Normal

ON: Alarm (CPU stop, alarm for each card)

Flashing: Alarm (MPR file error in restarting)

To AC Outlet

Advertising