4.1 Troubleshooting

238

Installation Manual

353

IP-PT DSP failure

IP-PT malfunction

The IP-PT will be rebooted
automatically if the error is temporary

Replace the corresponding IP-PT if the
IP-PT is not rebooted

355

IP-unit alive check
error

Optional service card
malfunction: IP-EXT

The IP-EXT card will be rebooted
automatically if the error is temporary

Replace the corresponding IP-EXT
card if the card is not rebooted

356

IP/TEL-unit
communication error

357

IP-unit FLASH
access error

Optional service card
malfunction: IP-EXT

Replace the corresponding optional
service card

358

IP-unit boot error

359

IP-unit DSP failure
(boot diagnosis)

360

IP-PT SUB-CPU
failure

IP-PT malfunction

The IP-PT will be rebooted
automatically if the error is temporary

Replace the corresponding IP-PT if the
IP-PT is not rebooted

361

IP-PT DHCP server
no response

DHCP server is not active

Network malfunction

Consult your network administrator

362

IP-PT Rebooted
(cause DHCP
server)

DHCP server is not active

Network malfunction

Network configuration has
been changed

Consult your network administrator

370

IP-GW Rebooted by
Maintenance
Console

IP-GW is rebooted from a
remote maintenance PC

This information is logged when IP-GW
is rebooted from a remote
maintenance PC

371

IP-GW Rebooted

Optional service card
malfunction: IP-GW

Check whether the software version of
the IP-GW card is correct

Replace the corresponding optional
service card

372

NDSS message over
IPGW notification -
caused by IPGW Tx
resource limitation

Optional service card
malfunction: IP-GW

Ignore if not frequent

Change the IP-GW card status to Out
of Service, and then back to In Service

373

NDSS message over
IPGW notification -
caused by IPGW Rx
resource limitation

374

NDSS message over
IPGW notification -
caused by shortage
of IPGW resource