4.1 Troubleshooting

Installation Manual

239

375

NDSS message over
IPGW notification -
caused by Network
side

Network malfunction

Ignore if not frequent

Consult your network administrator

390

Digital signal
synchronization
established

Synchronisation of digital
line established or
restored

This information is logged when
synchronisation of digital line is
established, and does not indicate an
error condition that needs to be solved

391

Data Link
established

Connection with PC
Phone/PC Console or
Voice Processing System
(DPT Integration)
established or restored

This information is logged when
connection with PC Phone/PC
Console or Voice Processing System
(DPT Integration) is established, and
does not indicate an error condition
that needs to be solved.
However, if this is logged frequently
(with "305 Data Link failure"), check the
connection as it may not be done
properly.

392

Clock master card
selected

Clock master card has
been changed to the one
indicated by the sub code

Check if the proper card is selected as
the new clock master card

393

LAN Carrier detected •

IP-GW card connected to
the LAN

This information is logged when
synchronisation of LAN is established

394

IP-GW Core Data
Link established

IP-GW Core Data Link
established

This information is logged when IP-GW
Core Data Link is recovered

395

IP-GW Gatekeeper
Error Cleared

Connection to the
Gatekeeper is recovered

This information is logged when
connection to the Gatekeeper is
recovered

396

IP-GW Run

IP-GW is started from a
remote maintenance PC

This information is logged when IP-GW
is started from a remote maintenance
PC

510*

SMDR disconnect

RS-232C cable not
connected

Breaking of RS-232C
cable

Printer (terminal
equipment) malfunction

Check the RS-232C cable

Check the terminal equipment

Error Code

Error Message

PROBABLE CAUSE

SOLUTION