D-Link KX-TDA100 User Manual

Page 232

Advertising
background image

4.1 Troubleshooting

232

Installation Manual

System Start-up and On-line Operation

Error Code

Error Message

PROBABLE CAUSE

SOLUTION

000*

MPR WDT overflow

MPR card malfunction

Optional service card
malfunction: CTI-LINK

Erroneous processing of
MPR card software

Software error due to
external factors

Press the Reset Button

Reprogramme the Hybrid IP-PBX

Replace the MPR card (be sure to turn
off the Hybrid IP-PBX when replacing)

001

SDRAM bit error

002

System Restart

Reset Button is pressed

Power failure

MPR card malfunction

Erroneous processing of
MPR card software

Software error due to
external factors

Ignore if not frequent

Press the Reset Button

Reprogramme the Hybrid IP-PBX

Replace the MPR card (be sure to turn
off the Hybrid IP-PBX when replacing)

010*

AC power down

Power supply system
malfunction (e.g., power
failure, power noise,
trouble with UPS)

Bad connection or
breaking of AC cord

Power supply circuit (PSU,
back board) malfunction

Check the power supply system

See if the AC cord is connected
properly

Check the AC cord

Replace the AC cord (be sure to turn
off the Hybrid IP-PBX when replacing)

Replace the PSU (be sure to turn off
the Hybrid IP-PBX when replacing)

Replace the back board (be sure to
turn off the Hybrid IP-PBX when
replacing)

011*

DC power down

AC power down

Power supply circuit (PSU,
back board) malfunction

Detection of over current
(short circuit on optional
service cards)

Check the power supply system

See if the AC cord is connected
properly

Check the AC cord

Replace the AC cord (be sure to turn
off the Hybrid IP-PBX when replacing)

Replace the PSU (be sure to turn off
the Hybrid IP-PBX when replacing)

Replace the back board (be sure to
turn off the Hybrid IP-PBX when
replacing)

Remove the optional service cards and
restart the Hybrid IP-PBX

012*

MPR RAM battery
low

Battery out

MPR card malfunction

Replace the MPR card (be sure to turn
off the Hybrid IP-PBX when replacing)

014*

FAN Alarm

PSU-L malfunction

See if anything is jammed in the fan

Replace the PSU (be sure to turn off
the Hybrid IP-PBX when replacing)

Advertising