Analog Way Smart Vu - SVU300 Programmer's Guide User Manual

Page 16

Advertising
background image

16

Group

Name

CmdResp Description

Read /
Write

Min
Value

Max
value

Default
value

Values

Index #1

Index #2

SIG_FORMAT_LIST

sL

sL

Bit field of the fomats compatible
with the detected format

Rd

0

255

0

0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
10 = Input11
11 = Input12

0 = Bits 0 to 7
Slice
1 = Bits 8 to 15
Slice
2 = Bits 16 to
23 Slice
3 = Bits 24 to
31 Slice
4 = Bits 32 to
39 Slice
5 = Bits 40 to
47 Slice

SIG_SCANTYPE

ss

ss

Input scan type

Rd

0

3

0

0 = Progressive
1 = Interleaved, Top field first
2 = Interleaved, Bottom field first
3 = Segmented frame

0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
10 = Input11
11 = Input12

SIG_HTOTAL_THEORIC

sH sH

Total number of pixels per line

Rd

0

65535 0

Unit = pixels

0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
10 = Input11
11 = Input12

SIG_HTOTAL_MAXI

sM sM

Maximal number of pixels per
input line

Rd

0

65535 0

Unit = pixels

0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
10 = Input11
11 = Input12

SIG_WIDTH

sw sw

Input displayed pixel count

Rd

0

65535 0

Unit = pixels

0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
10 = Input11
11 = Input12