Performing calibration and a configuration report, Configuration and configuration – Argox A Series User Manual

Page 20

Advertising
background image

A Series User’s Manual

39

Configuration and Configuration

This section discusses calibration, printing configuration and
resetting the printer to factory defaults.

Performing Calibration and a Configuration
Report

1. Make sure the media is properly loaded and the top cover of

the printer is closed.

2. Turn off the printer power.
3. Press and hold the FEED button while turning on the power,

until the printing motor is activated.

4. Media Calibration will be performed while the printer

automatically feeds the label stock for a certain length; then the
printer motor suspends for one second and then prints out
configuration/ self-test labels. Release the FEED button as
soon as printer starts to print

.

5. The profile includes firmware version, ROM checksum,

RS-232, thermal transfer/direct thermal settings, hardware
configuration, and font types.

6. At PPLB emulation, the printer enters character dump mode.
To exit from dump mode, press the feed button again. (If you
accidentally print the label without exiting from dump mode in

advance, you need to turn on the printer or press feed button
again to print normally.)

S

Important!

You must always carry out calibration when

changing media. Failure to do so will result in improper detection
by the label sensor.


A Series User’s Manual

40

Note:

When using A-2240E or A-2240ME models, if you do not

need configuration report, please press and hold the feed button
while turning on the power, wait after about 20-25 seconds,
release the feed button as soon as printer starts to feed a label.

Note: Revise the factory default settings that stored in
flash, even if turn off the power source cannot be eliminated.