5.1.16.3 Telecom Interrupt Control Register

Each of the Telecom interrupt source can be enabled.

5.1.16.4 RTM Interrupt Status Register

The RTM Interrupt Status Register will be located in the RTM SPI address space. The host can
access the RTM register using the RTM SPI Master Interface.

5.1.16.5 External Interrupt Status Register

Table 5-70 Telecom Interrupt Control Register

Address Offset: 0x23

Bit

Description

Default

Access

3: 0

Telecom CLK_MONITOR_FINISHED interrupt enable:
Enable/Disable interrupt for the corresponding Clock source:
0: interrupt is disabled
1: Interrupt is enabled

0

LPC: r/w

7:4

Telecom CLK_MONITOR_OUT_OF_RANGE interrupt:
Enable/Disable interrupt for the corresponding Clock source:
0: interrupt is disabled
1: Interrupt is enabled

0

LPC: r/w

Table 5-71 External Interrupt Status Register

Address Offset: 0x24

Bit

Signal/Group

Description

Default

Access

0

RTM_SPI_MISO

RTM interrupt sources
0: RTM_SPI_MISO is high. No RTM
interrupt.
1: RTM_SPI_MISO is low. One or more
RTM interrupt sources are active.
When RTM SPI Master face is active
the current level is latched.

Ext.

LPC: r