2 post diagnostic results, Table 9-2, Post diagnostic results–bit assignments – Artesyn ATCA-9305 User's Manual (May 2014) User Manual
Page 224: Management processor monitor
Management Processor Monitor
ATCA-9305 User’s Manual (10009109-07)
224
9.3.2
POST Diagnostic Results
The ATCA-9305 Power-On Self-Test (POST) diagnostic results are stored as a 32-bit value in I2C
NVRAM at the offset 0x07F0-0x07FF. Each bit indicates the result of a specific test, therefore
this field can store the results of up to 32 diagnostic tests.
assigns the bits to specific
tests.
Table 9-2 POST Diagnostic Results–Bit Assignments
Bit
Diagnostic Test
Description
Value
0
SDRAM
Verify address and data lines are intact
0 Passed the test
1 Failure detected
1
Flash
Verify size and initialization of soldered flash
2
I
2
C
Verify all local I2C devices are connected to
the I2C bus
3
Ethernet Switch
Verify PCI communication with switch
4
Reserved
5
PCIe Time-out
PCIe enumeration skipped by user
6
DOC Embedded Flash
Drive (EFD)
Verify presence and ability to access
configuration space of DOC
7
Cavium 1 Presence
Verify presence and ability to communicate
via PCI bus with Cavium 1
8
Cavium 2 Presence
Verify presence and ability to communicate
via PCI bus with Cavium 2
9-31
Reserved