Nsert, Nstallation, Fireplace sizing – Avalon Firestyles 700 B-Vent-1994 User Manual

Page 11: Vent requirements

Advertising
background image

I

NSERT

I

NSTALLATION

(C

ONT

.) -

For qualified installers only!

P

AGE

11

Fireplace Sizing

21" Minimum**

21" Minimum

24" Minimum*

24" Minimum

13" Minimum*

5 3/4" Minimum

* The gas inlet may be
located at the rear or on the
left side if the Side Inlet Kit
is used. Allow space for
gas hookup.

* * The extra space above
the heater is to allow
connection of the flue.

Vent Requirements

The vent must be installed in accordance with all local codes, if any; if not, follow ANSI 223.1
and the requirements listed below. Furthermore, the vent must be installed to meet the
installation requirements of the vent manufacturer.

¥

Minimum 5' vertical rise from top of stove (see the illustration below)

¥

4" listed gas chimney liner or B vent from one manufacturer (don't mix brands)

¥

Vent must reline the entire length of the chimney

¥

The vent must not service another appliance

¥

Must meet all of the vent manufacturer's requirements

NOTE:

When using flexible gas vent, do not crimp or rupture the liner when
bending it around a chimney offset

4" Listed gas chimney
liner or B Vent

Hearth and/or
hearth pad must
extend at least
to the faceplate

Z.C. (Metal)

firebox

Telescoping
Leg

6"

Min.

A sealed cover plate
is recommended,
but not required.

Surround

Panel

(Do not seal)

17"

Min.

Gas line with
shutoff valve

6"

Min.

17"

Min.

Leveling bolts for step-up hearths

Zero
Clearance
Fireplace

Surround

Panel

(Do not seal)

Approved Cap

Masonry
Fireplace