Avalon Firestyles 700 B-Vent-1994 User Manual

Page 13

Advertising
background image

I

NSERT

I

NSTALLATION

(C

ONT

.) -

For qualified installers only!

P

AGE

13

Manifold Pressure:

¥

Check the pressure of the gas downstream of the valve by removing the manifold
pressure tap with a 3/16" allen wrench (1/8" N.P.T. plug). If the manifold
pressure does not match the pressure listed in the table below, check the inlet gas
pressure and correct the problem.

Manifold Pressure with Regulator on HI

Natural Gas

3.5" W.C.

Propane

11" W.C.

Manifold Pressure Tap
(1/8" N.P.T. fitting)
Use a 3/16" allen wrench to remove.

The heater must be turned off while
connecting or disconnecting the
pressure tap or pressure sensing
device. Gas will ignite through the
pressure tap hole if the heater is on
and the pressure tap hole is open!

WARNING:

HI-LO Regulator

Gas Pressure:

Minimum Input Pressure

Natural Gas

5.5" W.C.

Propane

11" W.C.

¥

If the pressure is not sufficient, make sure the piping used is large enough, the
supply regulator is adequately adjusted, and the total gas load for the residence
does not exceed the amount supplied.

¥

The supply regulator (the regulator that attaches directly to the residence inlet or
to the propane tank) should supply gas at the suggested input pressure listed
above. Contact the local gas supplier if the regulator is at an improper pressure.

Purging the Gas Line:

The gas line must be properly purged to release all air in the gas line prior to starting the heater.

Finalizing the Installation

¥

Before starting, all gas line joints must be leak tested.

¥

Optional equipment must be installed (instructions are in the rear of this manual).

¥

The ceramic logs must be placed inside the firebox (see the section "Installing the
Logs and Coals" in the maintenance section of this manual).

¥

Start the heater and check for proper performance. Review the operations portion
of this manual to make sure the owner understands the operation of the heater.

Note: See the instructions "Re-Routing the Power Cord to the Left or Rear of the Heater" in the optional

equipment section of this manual to re-route the power cord.