Ptional, Quipment, Ontinued – Avalon Firestyles 700 B-Vent-1994 User Manual

Page 32: Remote control

Advertising
background image

P

AGE

32

O

PTIONAL

E

QUIPMENT

(C

ONTINUED

)

Remote Control

(Part # 99300651)

The remote control allows remote operation of the main burner. Follow the directions below to install.

1. With the gas shut off and the heater unplugged, remove the ashlip control housing by unscrewing

the three attachment screws with a 7/16" nutdriver. Carefully lay the ashlip control housing face
down in front of the heater.

Unscrew these three
bolts with a 7/16"
nutdriver to remove the
ashlip control housing

Ashlip Control Housing

Access Panel

2. Locate the 2" long green jumper wire. It can be found near the on/off switch. Remove the

jumper wire from the two green wires it attaches to (one leading to the on/off switch, the other to
the gas control valve).

3. The remote control receiver wire enters the ashlip control housing in the same location the power

cord does. Use a pair of slip joint pliers to remove the strain relief that holds the power cord in
place (see the illustration below). Unwind the remote control receiver wire and route the end
with quick connects through strain relief and to a location near the on/off switch. Insert the strain
relief back in the hole until it snaps into place.

Ashlip
Control
Housing

Power Cord

To remove the strain relief, use a pair
of slip joint pliers to press from the top
and bottom of the relief. Pull the relief
out once it becomes loose.

4. Attach the thermostat wire to the two green wires that were detached in step 2. Make sure to

route the remote control receiver wire through the notch in the ashlip control housing partition if
it entered through the center or left side (see the illustration below).

Route the thermostat through
the notch in the ashlip control
housing partition if it is coming
from the center or left side.
The thermostat wire attaches
to the green wire from the
valve and the green wire from
the on/off switch.

On/Off
switch

Piezo
igniter

Red wire
from valve

Orange wire from
spark electrode

Blower
Rheostat

Green wire
from valve

Green wire

Green Jumper wire
(remove and discard)

Ashlip Control Housing

Advertising