Approved Venting Configurations for Vertical Terminations with
(or without) Two 45¡ Elbows

¥

10Õ Minimum System Height
(with or without offsets)

¥

34Õ Maximum System Height

¥

6Õ Maximum Offset

¥

The termination must fall within the shaded area
shown in the chart. Use the indicated restrictor
position.

¥

If using offsets, use the table below to calculate
the vertical rise and horizontal offset

Offset
Length

Horizontal
Offset

Vertical

Rise

Offset Length

Hor. Offset

Vert. Rise

None

5 Ó

1Õ Section

1Õ 7Ó

2Õ Section

1Õ 9Ó

2Õ 4Ó

3Õ Section

2Õ 5Ó

4Õ Section

3Õ 2Ó

3Õ 8Ó

4Õ + 1Õ Section

3Õ 9Ó

4Õ 4Ó

4Õ + 2Õ Section

4Õ 6Ó

4Õ + 3Õ Section

5Õ 2Ó

5Õ 9Ó

4Õ + 4Õ Section

6Õ 9Ó

5 feet

10 feet

15 feet

20 feet

25 feet

30 feet

0 feet

34' (max)

0 feet

3 feet

6' (max)

5 feet

0 feet

0 feet

The maximum

offset lengths is

two 4' sections.

3 feet

6' (max)

10 feet

15 feet

20 feet

25 feet

30 feet

34' (max)

Restrictor

Position # 2

NOTE:

Restrictor positions

are based upon lab

tests. The ideal

restrictor position

may vary slightly,

especially when the

termination is near a

demarkation line.

Restrictor

Position # 3

Restrictor

Position # 4