Vertical terminations with two 90 elbows, Installation – Avalon Firestyles Vashon-1998 to 1999 User Manual

Page 12

Advertising
background image

12

Installation

(for qualified installers only)

Travis Industries

9 3 5 0 8 1 0 2

0 9 1 0 0 2

Approved Venting Configurations for Vertical Terminations with
Two 90¡ Elbows

¥

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.

0 feet

5 feet

(1.5 M)

10 feet

(3 M)

0 feet

0 feet

0 feet

NOTE:

Horizontal sections require a 1/4" (6 mm)

rise every 12" (300 mm) of travel.

16'(max)

(4.9 M)

5 feet

10 feet

(min.)

15 feet

20 feet

25 feet

30 feet

34' (max)

5 feet

10 feet

(min.)

15 feet

20 feet

25 feet

30 feet

34' (max)

5 feet

10 feet

16'(max)

Restrictor

Position # 4

Restrictor

Position # 3

NOTE:

Restrictor positions are

based upon lab tests.

The ideal restrictor

position may vary

slightly, especially when

the termination is near a

demarkation line.