Optional equipment – Avalon Firestyles Vashon-1998 to 1999 User Manual

Page 34

Advertising
background image

34

Optional Equipment

Travis Industries

9 3 5 0 8 1 0 2

0 9 1 0 0 2

Thermostat (Part # 99300650)

!

Do not connect 120 VAC to the gas control valve or wiring of this unit.

1

Route the thermostat wire through the back of the right side panel (there is a hole beneath the on/off
switch) and attach to the on/off switch (see the illustration below).

Remove the green
jumper wire.

Back of

on/off

switch

Attach the quick connects
from the wire to the two posts
on the on/off switch
(orientation does not matter).

c

d

Back of on/off switch

Open the right
side panel.

a

Route the
wire behind
the panel to
the on/off
switch.

b

2

Pull through all the slack on the wire (you may wish to wrap the wire in electrical tape to prevent
damage to the wire). Determine a location for the thermostat that is within range of the 50Õ length of
thermostat wire. It should be centralized in the room and away from the heater. The wire may be
routed externally on the wall or behind the wall (preferred).

3

Cut the thermostat wire so there is approximately 6" of slack (NOTE: Do not splice thermostat wires
togetherÐthis leads to too much electrical resistance). Follow the directions below to install the
thermostat.

50 60 70 80 90

50 60 70 80 90

Robertshaw

Run the thermostat wires

through the wall (cut off excess

wire, leaving 6Ó of slack).

Pull the cover off the thermostat

Expose 1/2Ó of wire and

attach to these two posts.

Standard

Screwdriver

Attach the thermostat to

the wall through these

two holes.

a

b

c

d

Re-attach the cover

removed in step ÒaÓ.

e

Advertising