Installation

(for qualified installers only)

9

Travis Industries

9 3 5 0 8 1 0 2

0 9 1 0 0 2

Approved Vent Configurations

Restrictor Position

¥

A vent restrictor is built
into the appliance to
control the flow rate of
exhaust gases. This
ensures proper flames
for the wide variety of
vent configurations. The
restrictor consists of a
butterfly valve in the air
inlet and an adjustment
plate with index holes
used to hold the valve in
a fixed position.
Depending upon the
vent configuration, you
may be required to adjust
the restrictor position.
The charts for approved
vent configurations
describe which position
the vent restrictor must
be in.

To Adjust the Restrictor:

2

3

4

The four holes on the restrictor
plate correspond to the four
restrictor positions.

Remove the screw with a 1/4"
nutdriver (or screwdriver).
Rotate the adjustment plate
counter-clockwise until the correct
index hole is above the pivot point.
Insert the screw into the correct
index hole and tighten.

NOTE:
Position #1 is the
fully open position

Swing the
right side
door open.

1/4" Nutdriver

1

2

3

4

Pivot
Point

Adjustment

Plate

Index
Holes

Screw

This restrictor is

in Position #2.

Determine the correct restrictor position (see the charts
under "Approved Vent Configurations" - the stock
position is #1). Swing the left access panel open.

1

Elbows

¥

2 Elbow
maximum
(two 45¡ or
two 90¡, not one
45¡ and one 90¡)

Measuring
Vent Lengths

Vent Horizontal Run
(measure from the closest
edge of the starter section to
the end of the termination)

Vent Height is
calculated to the
top of the vent on
horizontal
terminations and
to the top of the
termination on
vertical
terminations.

Vent

Height

Elbows add 3" to the length of
the vent system.

Side
View

9-5/8"

Vent Length
(3', 4', etc.)

Vent sections overlap each
other by 1-1/2"

8-3/4" wide with 1-1/2"
to 3-3/8" of overlap

The starter
section is 1-1/2"
above the top

12-3/8" tall with
1-1/2" of overlap

3"

1-1/2"

1-1/2"