4-16 Programmer’s Manual

Field Description

VerifyCD

Enables/disables the ability to check the integrity of
Code 39 bar codes. When this parameter is enabled,
only Code 39 symbols with a modulo 43 check digit
are decoded. Default: false

XmitCD

Enables/disables the ability to transmit check digits
with the data. Default: false

FullASCII

Enables/disables the ability to scan Full ASCII Code
39 bar codes. The scanner cannot distinguish Code
39 bar codes from Full ASCII Code 39 bar codes. Do
not enable Trioptic and FullASCII at the same time.
Default: false

Return Values

None