Field Description

XmitUPCAPre

Specifies how to transmit UPCA Preamble characters.
Values are:
1 = XUP_NONE Do not transmit.
2 = XUP_SYSCHAR Transmit system character.
3 = XUP_SYSCOUNT Transmit system character and

country code.

Default: XUP_SYSCHAR

XmitUPCEPre

Specifies how to transmit UPCE Preamble characters.
Values are:
1 = XUP_NONE Do not transmit.
2 = XUP_SYSCHAR Transmit system character.
3 = XUP_SYSCOUNT Transmit system character and

country code.

Default: XUP_SYSCHAR

XmitUPCE1Pre

Specifies how to transmit UPCE1 Preamble characters.
Values are:
1 = XUP_NONE Do not transmit.
2 = XUP_SYSCHAR Transmit system character.
3 = XUP_SYSCOUNT Transmit system character

and country code.

Default: XUP_SYSCHAR

XlateEtoA

Translates a UPCE bar codes to a UPCA bar code.
Default: false

XlateE1toA

Translates a UPCE1 bar codes to a UPCA bar code.
Default: false

EANZeroExtend

Adds five leading zeros to scanned EAN8 bar codes to
make them compatible with EAN13 bar codes.
Default: false

Xlate8TO13

Translates an EAN8 bar code to an EAN13 bar code.
Default: false

Security

Sets the scan security level, which is how many times
to scan the same bar code to determine a successful
read. Choose the minimum-security level needed.
Values are
0 Use when most scans are successful.
1 Use when the unsuccessful scans are related

to characters 1, 2, 7, and 8.

2 Use when the unsuccessful scans are not limited

to characters 1, 2, 7, and 8.

3 Choose 4 if unsuccessful scans still occur at

level 2. Default: 0