Mxxxz13[y]<cr, Mxxxz20[“baud”]<cr, Mxxxz64[xxx.xxx.xxx.xxx]<cr – AVocation Systems HX-0808HA/8 User Manual

Page 23

Advertising
background image

D18

MXxxZ13[y]<CR>

Read Front Panel Control Status

MX00Z13<CR>

Response: MXxx-Front Panel is unlocked<CR>

Disable Front Panel Control

MX00Z130<CR>

Response: MXxx-Front Panel is locked<CR>

Enable Front Panel Control (default mode)

MX00Z131<CR>

Response: MXxx-Front Panel is unlocked<CR>

MXxxZ20[“baud”]<CR>

Read Current Serial Baud Rate

MX00Z20<CR>

Response: MXxx-RS-232 baud = 19200<CR>

Set Serial Baud Rate

MX00Z20”19200”<CR>

Baud Rates

4800

9600

19200

38400

57600

115200

Response: MXxx-RS-232 baud = 19200<CR>

MXxxZ64[xxx.xxx.xxx.xxx]<CR>

Read matrix IP Address

MX00Z64<CR>

Response: MXxx-IP Address is 192.168.000.075<CR>

Set matrix IP Address

MX00Z64192.168.000.075<CR>

Set matrix IP Address to 192.168.009.075

Response: MXxx-IP Address is 192.168.000.075<CR>