Configuration via twincat system manager, 4 configuration via twincat system manager – BECKHOFF FC9001-0010 User Manual

Page 35

Advertising
background image

Configuration via TwinCAT System Manager

4 Configuration via TwinCAT System Manager

In the left-hand window of the TwinCAT system manager, click on the Ethernet channel you wish to
configure (in the example: device 2 (RT Ethernet)).

In the right-window of the TwinCAT system manager, various tabs, i.e.

- General tab
- Adapter tab
- EtherCAT tab
- Statistics tab
- Diagnostics tab

are now available for configuring this Ethernet channel.

Numbering of the Ethernet channels

Note

The system manager numbers the Ethernet channels (device 1, device 2 ...) in the
order in which it recognizes them as ready for real-time Ethernet. This numbering does
not have to correspond to the numbering of the LAN connections in the network
connections of the Windows Control Panel or the numbering of the RJ45 sockets on
the FC900x (X1, X2 ...).

The channels of an FC9002/FC9004 can be identified via their unique MAC addresses.

FC90xx

33

Advertising
This manual is related to the following products: