Chapter 4, Comunication interfaces, Serial interface – Bematech KB-1800 User Manual

Page 16

Advertising
background image

U

S

e

R

’S

MANU

A

l KB

-1800

·

R

evision 1.3

16

Figure 15

25

................

24

................

23

................

22

................

21

................

20

................

19

................

18

................

17

................

16

................

....................

13

....................

12

....................

11

....................

10

....................

09

....................

08

....................

07

....................

06

....................

05

....................

04

....................

03

Chapter 4

Comunication Interfaces

Communication between a host and the printer can be performed in three communication protocols: USB, Parallel
or Serial RS-232, according to the printer model.

Communication cables are not supplied with the printer

Serial Interface

The RS232 serial interface uses a female DB-25 connector. The serial port can operate using the DTR/DSR mode,
with 7 or 8 data bits, with or without parity, even or odd parity, one start bit and one or more stop bits. In the RS232
standard, the logic low level corresponds to a +12V voltage level and a logic high level corresponds to -12V.

DTR / DSR mode

In this mode, the printer’s DTR line controls the flow of data sent from the host’s TX line and received by the printer’s
RX pin. In this case, when the printer’s DTR signal is low (+12V) the printer requests the host to send data. When
the DTR signal is high (-12V) the printer tells the host to stop sending data.

DB-25 Serial connector

The serial cable needed for the DTR / DSR mode is shown below:

Printer Side (DB-25)

Host Side (DB-9)

2 (TD)

2 (RD)

3 (RD)

3 (TD)

6 (DSR)

4 (DTR)

7 (GND)

5 (GND)

20 (DTR)

6 (DSR)

1-7-8 (jumper)

Printer Side (DB-25)

Host Side (DB-25)

2 (TD)

3 (RD)

3 (RD)

2 (TD)

6 (DSR)

20 (DTR)

7 (GND)

7 (GND)

20 (DTR)

6 (DSR)

4-5-8 (jumper)