Boyertown Regal Oil Fired Furnace Variable Speed 2 Stage ECM Motor User Manual

Page 23

Advertising
background image

Oil Burner

Refer to the oil burner instruction manual provided with the burner for proper

aintenance and service.

m

NOTICE

Burner Components: If replacement of burner parts is necessary, always use parts recommended by
the manufacturer. Specify part number and description when ordering.

Electrode settings are important for reliable ignition of the oil. Check to be sure the settings are in ac-
cordance with the instructions provided in the burner manual.

Nozzles: ANY NOZZLE REPLACEMENT SHOULD BE OF THE EXACT TYPE AS THE
ORIGINAL SUPPLIED BY THE MANUFACTURER. Use extreme care in handling nozzles to avoid
scratches or dirt that could cause leaks or affect the oil spray pattern.

Perform the combustion checks as per the burner manual and the furnace manual.

Blowers - Direct Drive

Clean inspect blower wheel annually. Lubricate blower motor as per the motor manufacturer’s
recommendations.

Vent System

Clean and inspect the flue pipe draft regulator and chimney annually as outlined in this manual.

Fuel Oil System

Check oil tank and piping for leaks annually, replacing the oil filter to avoid contamination of the fuel
unit and nozzle.

Filters

Air filters should be inspected and replaced if required monthly. The filters supplied with the furnace
are disposable and need to be replaced with the exact type and size as supplied. Dirty or clogged air
filters will impair the furnace performance and may cause the furnace to shut down or overheat.

Do not add additional filters unless the duct system is sized to allow for the additional pressure drop.

23