10 .....programming instructions, Cwp-1570 control panel, cont’d, Programming – BUG-O Systems CWP-5 User Manual

Page 9

Advertising
background image

9

KEYPAD

The keypad (Item 12 on page 8) is the second section of the control panel. This is used for programming

and inputting dimensions. Refer to the section titled “Programming” (below) for more detailed information. An

overview of the key functions is provided below.

ALPHA KEYS

Press keys A, B, C, D, or E for the function desired, as described in the

“Programming” section of this manual.

DIGIT KEYS

Use the digit keys to enter pipe diameters or dimensions.

ENTER

Push the ENTER button to store the numeric value entered.

BACKSPACE

Use BACKSPACE to remove the last digit keyed in before pushing the ENTER

button, if a correction is required.

SHIFT

The blank key in the top right corner of the keypad is the SHIFT key. Use this key

to access additional programming options.

ARROW KEYS

Used to jog vertical axis during auto-run program to set new torch position.

CWP-1570 CONTROL PANEL, CONT’D.

ROTATION CONTROLS

The rotation controls are located on the left portion of the control panel (Items 1-11 on page 8). Use these

controls to maneuver the electrode to the starting position, to start or interrupt the weld and to control the

rotation speed. A brief description of each item is provided below.

ROTATION SPEED

Displays reference # only

SPEED CONTROL

Controls speed of rotation. Turn right to increase; left to decrease

STOP / PAUSE

Immediately stops welding and rotation. Does not burnback or purge

START / RESUME

Starts or resumes program

RESET

Resets home or weld start position

MANUAL JOG

Manually position welding electrode for vertical and horizontal axes

CONTROL POWER

Enables / Disables power to control panel

POWER INDICATOR

When lit, indicates power ON to control panel

CIRCUIT BREAKER

Protects control box electronics

MIRROR IMAGE

Reverses rotation direction

WELD ON/OFF

ON enables weld. OFF disables weld for dry run

PROGRAMMING

FUNCTION KEYS

All programming is done using the

PENDANT CONTROL. Use the following Alpha Keys for programming:

A: To enter dimensions.

B: To enter the time delay for puddle build-up.

C: To change Program Number in memory (numbers 0 – 99).

D: To display the dimensions of the weld.

E: To enter the number of passes (1 – 99).

Three other useful key functions are:

Shift 9: Set units, English (inch) or metric (meters)

Shift 8: Test drives & encoders

Shift E: Version number (have this information ready when calling for service)

DATA REQUIRED

1. Small diameter (nozzle size)

2. Large diameter (pipe it fits on)

3. Offset distance between centerlines