39

Refer to CWE-5 Electrical Component Chart. (Pg. 18)

CWE-5 Collector item #9:

The collector ring should be sanded once a year. If the collector ring is pitted too badly it should be replaced.

Inspect all wires coming out of the collector ring for cut or missing insulation. All wires should be fastened to the

center shaft with a nylon cable tie. Tighten four set screws if needed.

Weld Cable Inlet 2/0 item #1:

Ensure that the cable is fastened tightly to the collector ring. Inspect the cable for cut or missing insulation. Make

sure the micarta insulation tube on the cable is in good condition. Replace the cable if necessary.

Solenoid Adaptor Kit item #14:

Inspect for damage. Replace if necessary.

GMA Pigtail item #6:

Inspect the cable for cuts or missing insulation. Ensure that the elbow connector is not damaged. Ensure that all

terminal ends are snug. Replace cable if necessary.

PREVENTIVE MAINTENANCE / CWE-5 CIRCLE WELDER