CWE-1000-B PROGRAMMABLE ROTATION CONTROLS, CONT’D.

(L) CYCLE START SWITCH:

In the AUTOMATIC WELD mode the CYCLE START SWITCH initiates the automated weld cycle.

(M) MANUAL / AUTOMATIC WELD SWITCH:

The manual position allows the operator to rotate the machine without welding to check the wire

placement as well as the cam setting. The automatic position enables unit for complete automatic cycle.

Press (L) to initiate automatic cycle.

(N) PILOT LIGHT:

The pilot light indicates whether the machine is on/off as dictated by the on/off switch.

(P) ON / OFF SWITCH:

The on/off switch enables/disables the power to the Rotation Control Box.

(Q) 2 AMP SLOW BLOW FUSE

(R) RESET CIRCUIT BREAKER FOR WIRE FEEDER

(S) EMERGENCY STOP BUTTON:

In case of a emergency press button in the DOWN position to stop ALL functions of the machine. To

deactivate the EMERGENCY STOP rotate clockwise.

(T) GLP RESET FOR WIRE FEEDER:

Protects unit if weld current ground is lost.

(U)

ROTATION SENSOR ON/OFF

:

Control sensor so the unit can be used for single pass if ON / multipass if OFF.

(CN1) CONNECTOR:

Power input and contact cable from the welding power source.

(CN2) CONNECTOR:

Cable connection to the machine for wire feed and rotation motor.

(CN3) CONNECTOR:

Homing sensor cable from machine.

Advertising