GAS CONNECTION

Before connecting the appliance check that the

data on the rating plate affixed to the cooker,

correspond to those of the gas mains.

A label on the back of this handbook and at

the back of the cooker gives the appliance

adjustment conditions, that is, the type of gas

and operating pressure.

Once the cooker is installed, check there are no

leaks using a soapy solution (never a flame).

The appliance’s gas inlet fitting is a threaded 1/2”

male cylindrical type, in compliance with the ISO

228-1 standards. If gas is distributed through ducts

the appliance must be connected to the gas mains with:

a rigid steel pipe, in accordance with standards,

whose joints must be made using threaded fittings

in accordance with the UNI-ISO 7/1 standard. The

use of hemp with suitable adhesives or Teflon tape

as a sealant is allowed.

copper pipe, in accordance with the standard,

whose joints must be made using sealed fittings in

accordance with the standard.

a flexible stainless steel, seamless pipe in

accordance with the standard, with a maximum

2 metre extension and seals in accordance with

the standard.

a flexible rubber hose in accordance with the

standard, with an 8 mm diameter for LPG and

13 mm for natural gas or town gas, maximum

1500 mm in length, firmly secured to the hose

fitting with a safety clamp as per the standard.

If the gas is supplied directly from a gas cylinder,

the appliance, fed by a pressure regulator in

accordance with the standard, must be connected:

with a copper pipe in accordance with the standard,

whose joints must be made using sealed fittings in

accordance with the standard.

with a flexible stainless steel, seamless pipe in

accordance with the standard, with a maximum

2 metre extension and seals in accordance with

the standard. We recommend applying the special

adapter to the flexible pipe, easily found on the

market, to facilitate connection to the pressure

regulator’s hose fitting on the cylinder.

with a flexible rubber hose in accordance with

the standard, with an 8 mm diameter, minimum

400 mm in length, maximum 1500 mm in length,

firmly secured to the hose fitting with a safety

clamp as per the standard.

INSTRUCTIONS FOR THE INSTALLER

ATTENTION:

• If the appliance is going to be recessed (class 2

subclass 1), connect it to the gas supply source

using only flexible stainless steel, seamless

pipes in accordance with the standard.

• If the appliance is going to be installed free-

standing (class 1) and if you use the flexible

rubber hose, it is necessary to follow the

instructions given below:

• On its route, the hose must not touch any

parts where the over temperature is more than

70 K.

• The hose must not be subject to any kind of

torsional stress or tractive force, there must

be no pinched parts or really sharp bends.

• It must not touch anything that can cut, that

has sharp corners, etc.

• The whole length of the hose must be easy

to inspect in order to keep a check on its

condition.

• It must be replaced within the date printed on

it.