Instructions for the installer, 26a 26b – Campomatic C964XRSIFSCN User Manual

Page 32

Advertising
background image

32

27

26a

26b

ADJUSTMENTS

• Always disconnect the appliance from the electricity supply before making any adjustment.

• All seal must be replaced by the technician following any adjustment or regulation.

• The adjustment of the reduce rate (simmer) must be undertaken only with burners functioning on

natural gas while in the case of burners functioning on L.P.G, the screw must be locked down fully

(in clockwise direction).

• “Primary air adjustment” on hob gas burners is unnecessary.

TAPS

All gas taps are male cone type with only one way of

passage. Adjustment of the “Reduced rate” position

as follows:

• Turn the burner on and place the knob on the

“Reduced rate” position (small flame).

• Remove the knob (A) of the tap which is attached by

simply applying pressure to the rod.

• Insert a small screwdriver (C) into hole (F) (fig. 26a)

and turn to the right or left the throttling cone until

the flame of the burner is conveniently regulated to

the Low position.

• In the case of taps with flame failure device, the

adjustment screw (V) is on the side of the stem (fig.

26b).

• Check that the flame does not go out when the knob

is sharply switched from the “Full on” to “Reduced

rate” positions.

ATTENTION!! This operation can be carried out

also with the front panel fitted, but if the technician

finds some difficulties to reach the adjustment

screw, remove the front panel unscrewing the fixing

screws (Vf) (fig. 31), which are positioned in the

inferior part of the same.

OVEN THERMOSTAT (fig. 27)

Reduced rate adjustment should be carried out in

the following way:

• Remove the knob thermostat.

• Switch on the oven burner by turning the relative

knob to the Maximum position, then wait about 10

minutes.

• Slowly turn the knob back to the Minimum position

and, using a small screwdriver (C), turn screw (V) to

the right to lower the flame or to the left to increase

it. The flames must be short for an efficient Reduced

rate setting. They must be stable to prevent them

from accidentally going out and must be able to

stand up to normal oven door manoeuvres.

INSTRUCTIONS FOR THE INSTALLER

Advertising
This manual is related to the following products: