Instructions for the installer

10. INSTALLATION

Before installation

Installation and test must be carried out by professional technician. And the hob must be 150mm far away

from the wall or anything else. To avoid interference of taking the households when cooking, in the place

300mm from the both sides of the hob must not be put any furniture or separate board. And the both sides

of the hob should 300mm at least far away from the wall. The thickness of the table used to mounting the

hob should be 30cm at least, and it should be heat resisting or be covered by a the heat resisting material.

10.1 Technical information

Model

12’’ serial

24’’ serial

28’’ serial

30’’ serial

Voltage(V)

220-240

Frequency(Hz)

50-60

Outer size(mm) 290x510x55 580x510x55 680x510x55 770x510x55

Cast

dimension(mm)

270x490

560x490

560x490 750x490


10.2 The rating plate

Make sure that the voltage and capacity of the power
line conform to the data shown on the
plate located under the casing. Do not remove this
plate for any reason.







10.3

Electrical connection

IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE
METHODS REQUIRED BY SAFETY RULES.

BEFORE THE APPLIANCE BEING CONNECTED WITH THE MAINS, PLEASE DO ASSEMBLE ONE
FULLPOLAR BREAKER WITH OVER 3MM OPENED ON THE MAINS,AND THE RATED CURRENT
OF THE BREAKER IS STRONGLY RECOMMENED OVER 40A.
.
NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE
HOB, FOLLOWING THE INSTRUCTIONS. IF THE HOB FAILS TO OPERATE, AFTER CHECKING
THAT YOU HAVE CARRIED OUT THE INSTRUCTIONS CORRECTLY, DISCONNECT THE
APPLIANCE FROM THE ELECTRICAL MAINS AND CONTACT YOUR NEAREST SERVICE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
IF A PLUG AND SOCKET CONNECTION IS BEING USED MAKE SURE THAT THE PLUG
AND SOCKET ARE COMPATIBLE. AVOID USE OF ADAPTERS AND SHUNTS AS
THESE COULD CAUSE OVERHEATING AND RISK OF BURNS.

IF A FIXED CONNECTION IS BEING USED FIT POWER LINE WITH AN OMNIPOLAR CIRCUIT
BREAKER WITH A CONTACT OPENING GAP EQUAL TO OR GREATER THAN 3 MM
IN AN EASILY ACCESSIBLE POSITION IN PROXIMITY TO THE HOB.