Lubrication of the gas taps, Table for the choice of the injectors – Caple CR9215 User Manual

Page 19

Advertising
background image

If the gas tap becomes stiff, it is necessary to dismount it accurately clean it with
gasoline and spread a bit of special grease resistant to high temperatures on it.

The operations must be executed by a qualified technician.

IMPORTANT
All interventioni regarding installation maintenance and conversion of the appli-
ance must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.

Lubrication of the gas taps

TABLE FOR THE CHOICE OF THE INJECTORS -

Cat:

II

2H3+

GB

19

I

NCREASE OF AIR NECESSARY FOR GAS COMBUSTION

(2 m

3

/h x kW)

BURNERS

Air necessary for combustion [m

3

/h]

Auxiliary (A)

2,00

Semi-rapid (SR)

3,50

Rapid (R)

6,00

Triple-ring (TR)

7,00

Left Oven

7,40

Left Grill

5,00

Right Oven

4,40

BURNERS

Auxiliary (A)

1,00

0,30

50

-

72 (X)

-

Semi-rapid (SR)

1,75

0,45

65

-

97 (Z)

-

Rapid (R)

3,00

0,75

85

-

115 (Y)

-

Triple-ring (TR)

3,50

1,50

95

-

135 (T)

-

Left Oven

3,70

0,75

92

fully open*

140

5 *

Left Grill

2,50

-

80

fully open*

120

4 *

Right Oven

2,20

0,63

72

fully open*

110

4 *

Nominal

Power

[kW]

Reduced

Power

[kW]

G 30 - 28-30 mbar

G 31 - 37 mbar

G 20

20 mbar

Ø injector

[1/100 mm]

Ø injector

[1/100 mm]

*

= Reference value

Ring opening

[mm]

Ring opening

[mm]

Advertising