Left and right ovens, Regulating of the oven minimum – Caple CR9215 User Manual

Page 23

Advertising
background image

23

LEFT and RIGHT OVENS

Regulating of the oven
minimum

This needs to be done only for the
oven burner (the grill of the left oven
is a fixed capacity) by acting on the
thermostat.

Considering that in the minimum posi-
tion the flame must have a length of
about 4 mm and must remain lit even
with a brusque passage from the max-
imum position to that of minimum.
The flame adjustment is done in the
following way:

– Light the oven taking the knob to

max. position

(230

)

.

– remove the knob and by a thin screw-

driver (3 mm section - 100 mm long)
unscrew of about a half turn the
screw by-pass G, passing through
the front panel hole (fig. 3.16)

– fit the knob and let the oven heat for

10 minutes, then take the knob to
position

130

allowing the thermostat

to work under by-pass.

– after further removal of the knob, stop

slowly the screw by-pass G (being
careful not to turn the knob rod) until
the flame reaches 3-4 mm high.

N.B. For LPG the by-pass screw must
be fixed thoroughly.

Fig. 3.16

Flame correct

Flame faulty in
primary air

Flame with excess
primary air

G

Flame

faulty in

primary air

Flame

correct

Flame

with excess

primary air

long, yellow

and

trembling

clear

interior blue

cone

short and sharp
too blue interior
cone tending to

detach

CAUSE

air regulating

tube, too

closed

correct

distance of

the tube

air regulating

tube, too

open

Advertising