Cata HGR 110 AS WH User Manual

Page 39

Advertising
background image

FITTING THE APPLIANCE (see Fig. 5)

These appliances are classified as Class I.

The earth is obligatory as provided for by law. The manu-

facturer declines all liability in the event that the accident

prevention rules have not been followed.

IMPORTANT

The adjacent piece or furniture or cupboard and all the ma-

terials used in the installation must resist a minimum tem-

perature increase of 85 ºC above the ambient temperature

during use of the appliance.

Certain types of vinyl or laminated kitchen furniture are

particularly susceptible to damage due to decolouration at

temperatures below those indicated.

If the appliance is installed without paying attention to this

temperature limit or if it is placed less than 4 mm from the

adjacent cupboards, liability will belong to the owner.

INSTALLATION NOTES

1. The oven has to be installed in a standard gap of 600mm,

as indicated in Fig. 5, whether under a hob or in a column.

2. On inserting the oven in a column, it is essential in order

to ensure there is enough ventilation, to remove the rear

panel of the furniture and have an opening of at least 85-

90mm as indicated in Fig. 5.

3. Check that the oven has been fixed securely in the housing.

Fixing the oven into the cupboard is done using 4 screws “A”

Fig.5. One in each corner of the oven door frame.

Fig. 5: Installation distanced for simple electric ovens of

60 cms wide (the shape of the upper casing may vary) and

attachment to the cupboard.

A. The support runner must be removed

B. Spacing of 75-90 mm between the wall and the rear part

of the support shelf and the base of the cupboard

C. Base

D. False box front to be assembled

Fig. 7: Ventilation and gap requirements for the installation

of e simple electric oven in a standard cooking unit.

Minimum ventilation requirements for upper, base and sup-

port shelves for the rear part of the unit.

A. Rear panel

B. Storage space

C. Remove the rear part of this section

D. Real panel

E. Storage space

F. Base

G. Minimum ventilation gap 80 cm2

Fig. 8: Ventilation and gap requirements for the installation

of a simple electric oven in an upper cupboard.

Advertising