ELECTRICAL CONNECTION

Before connecting the appliance, check that the voltage

marked on the specifications plate coincides with the volta-

ge of the electricity network.

The NICEIC register is recommended for electrical installa-

tions.

WARNING – THIS APPLIANCE MUST BE EARTHED

This appliance must be wired to a 13 A bipolar automatic

switch with protected socket, which has a 3 mm separation

between contacts and is placed in an easily accessible pla-

ce next to the appliance.

IMPORTANT

The conductors of the network power supply lead are co-

ded by colours are follows:

Green and yellow -Earth

Blue - Neutral

Brown - Live

• The green and yellow conductor must be connected to

the terminal marked “E” or with the symbol of the earth or

which is green and yellow.

• The blue conductor must be connected to the terminal

marked “N”.

• The brown conductor must be connected to the terminal

marked “L”.

• The lead must not reach a temperature higher than 50 ºC

above the ambient temperature at any point.

• If the power lead is damaged, it must be replaced by a

special lead or unit supplied by the manufacturer or it after-

sales service.

REPLACEMENT OF THE NETWORK POWER SUPPLY LEAD

If it is necessary to replace the network power supply lead,

proceed as follows:

1. Disconnect the appliance from the power supply, uns-

crews the fastening screws and remove the rear panel.

2. Unscrew the fastening screws and those of the terminals

to free the existing lead.

3. Assemble the replacement lead which must comply with

the information listed in the Specifications, ensuring the co-

rrect connection of the colour codes and that all the screws

are correctly tightened.

MAINTENANCE

Before carrying out maintenance, disconnect the appliance

from the power supply.

During the guarantee period, if necessary all services

should be commissioned to the Manufacturer’s Technical

Assistance Service Department. Bear in mind that interven-

tion or repair by unauthorised personnel will invalidate this

guarantee.

REPLACEMENT OF THE OVEN LIGHTBULB

(Not covered by the appliance guarantee.)

The oven has a light with the following characteristics: 15 W

or 25 W, 300 ºC and type E-14

WARNING: Disconnect the appliance from the electricity

supply, remove the oven door (as described above), as well

as the oven shelves.

Remove the glass cover that protects the light bulb by tur-

ning it anti-clockwise. Fig. 9 (A)

Unscrew the old light bulb and dispose of it safely and eco-

logically, change it for one as specified in the Specifications

and replace the cover.

NOTE – The glass cover may be tight and, therefore, may

need a grip to release it.

CARE AND REPLACEMENT OF THE CATALYTIC COVERING

(When assembled, the covering is not covered by the

appliance guarantee).

In order to keep the covering “always clean” efficiently,

the oven must be heated to a minimum of 200 ºC whene-

ver there are stubborn stains, so that they do not become

permanent.

If the covering becomes black and shiny, they must be re-

placed. Remove all the internal accessories to facilitate the

replacement of the covering.

The replacement covering may be bought directly from the

Manufacturer’s Replacement Part Department (see details

included in the cover). Indicate the reference numbers of

the product type described in the specifications plate and/

or the series number of the appliance on ordering.