A.3 s, A.3.1 c – Comtech EF Data SDM-2020 User Manual

Page 186

Advertising
background image

SDM-2020 Satellite Modulator

Revision 7

Remote Control Operation MN/SDM2020M.IOM

A-16

Parameter

Type

Command/Status/

Response

Description of Arguments

Comments

Alarm Relay
State

Command:
Response:

Status:
Response:

<add/ARLY_xxx'cr'
>add/ARLY_xxx'cr''lf']

<add/ARLY_'cr'
>add/ARLY_xxx'cr''lf']

Where: xxx = NRM (normal sense) or INV
(inverted sense).

This command controls the logic sense of the
Mod alarm relay (NC and NO contacts).

A.3

S

TATUS

C

OMMANDS

/R

ESPONSES

A.3.1

C

ONFIGURATION

S

TATUS

Parameter

Type

Command/Status/

Response

Description of Arguments

Comments

Modulator
Rate

Command:
Response:

<add/MR_'cr'
>add/MR_nnnnn_mmm.mmmmmm'cr''lf']

Where:

nnnnn = 1/2 (QPSK 1/2) [Coder rate], 3/4
(QPSK 3/4)
7/8 (QPSK 7/8), 5/6 (QPSK 5/6), 2/3 (QPSK
2/3), 8P23 (8PSK 2/3), 8P56 (8PSK 5/6),
8P89 (8PSK 8/9), 16Q34 (16QAM 3/4), 16Q78
(16QAM 7/8).

mmm.mmmmmm = Data rate in MHz.

Note: When using a SMPTE 310M interface,
the data rate is fixed at 19.392658 MHz. While
the code rate can be changed as applicable,
an invalid parameter message will be
generated if any other data rate is input for
change.