2-2

Table 2-1. General Specifications (Continued)

Parameter

Specification

Energy
Dispersal

EN 300 421 and prEN 301 210 , or None

Spectral Sense Normal or Inverted

Front Panel
Interface

Keypad + LCD with back lighting

M&C Interface

Programmable selection for EIA-232, 2-wire EIA-485 or 4-wire EIA-485, 9-pin D female connector,
serial, ASYNC

Fault/Alarm
Interface

Status Relays

Max. Current
Voltage

Form C, 9-pin D, female connector

TX Fault, TX Alarm, Common Equipment

< 30 VAC, 42.4 Vpk-pk, or 60 VAC

Unit Cooling

Exhaust fan located on the left of the unit when viewed from the rear.

Rated AC
Power Input

100 to 240 VAC, 50 to 60 Hz; 1.0A at 100 VAC or 0.5A at 240 VAC. Connection universal type IEC
320.

40W typical, 65W maximum.

Note: This equipment is fitted with a wide-ranging power supply that will operate at +6% to –10% of
the rated voltage range.

IEC 950, Paragraph 1.6.5.

Power
Distribution
System

Type TN only (EN 60950 Paragraph 1.2.12.1).

Note: The equipment shall not be used with single-phase three-wire and PE.

Connection to
Supply

Pluggable equipment Type A (EN 60950, Paragraph 1.2.5).

Note: Equipment which is intended for connection to the building power supply wiring via a
nonindustrial plug and socket outlet or a nonindustrial appliance coupler or both.

Power Supply
Fuses

Double pole fused.

Fuse type 20mm 2A T-type HBC (T2A H250V)

(IEC 127, Sheet V, approved and UL recognized)

Class of
Equipment

Class 1 Equipment (EN60950, Paragraph 1.2.4): electric shock protection by basic insulation and
protective earth.

Power Supply
Hold-up

16 ms minimum at 120 VAC

78 ms minimum at 240 VAC

DC Power
Input optional

42 to 56 VDC. 40W typical, 65W maximum.

CE
Compliance

Required