2 faults/alarms:tx interface – Comtech EF Data SDM-2020 User Manual

Page 62

Advertising
background image

SDM-2020 Satellite Modulator

Revision 7

Front Panel Operation

MN/SDM2020M.IOM

5-20

5.6.5.2

FAULTS/ALARMS:TX INTERFACE

TX INTERFACE

------- -

Selections available include the following:

Fault/Alarm

Possible Problem and Action

FRAME SYNC

Indicates that the modulator cannot synchronize to the data in the selected
framing mode.

DATA STABLE/ASI

Note: ASI is an alarm,
not a switching fault.

Data or ASI.
When data fault is selected in the Interface Configuration menu, the fault indicates
a data stable condition. This indicates the data is all 1s or 0s (i.e., data is not
transitioning).
When ASI is selected, the alarm indicates the data is all 1s from customer data
input to the modem. When None is selected in the Configuration Interface menu,
the TX Data/ASI Fault/Alarm is not activated.

CLOCK PLL

Transmitter phase-locked loop fault. Indicates the transmitter Phase-Locked Loop
(PLL) is not locked.

CLOCK ACTIVITY

Activity detector alarm of the selected interface TX clock. The interface will fall
back to the internal clock when this alarm is active.
Note: Refer to the Configuration Interface menu, TX CLK ACTIVITY. This menu
permits selection of a fault or an alarm indication for clock activity.

FIFO

This fault indicates a data under-run/over-run condition.

INTERFACE MODULE

Interface module fault. Indicates a problem in programming the interface. This
could indicate a problem in the M&C, or in the interface between the interface
section and M&C. Return the modulator for repair.

DATA FORMAT

This fault indicates a fault with the formatted data.

VIDEO FRAME SYNC

Video Frame SYNC fault. This fault indicates a loss of synchronization to
incoming video data.

1

Use the [

←] [→] arrows to make a selection.

2

Press <ENTER>.