Comtech EF Data KST-2000A/B User Manual

Page 175

Advertising
background image

Ku-Band Satellite Transceiver

Revision 9

FSK Remote Control Commands

MN/KST2000AB.IOM

E-23

Parameter
Type

Command
(Instruction
Code and
qualifier)

Arguments for
Command or
Response to
Query

Description of arguments
(note that all arguments are ASCII numeric codes, that is, ASCII
codes between 48 and 57)

Response to Command (target to
controller)

Query
(Instruction
Code and
qualifier)

LNA Stored
Faults

n.a.

1 byte

Query only.
<add/LSF?X’cr’
>add/LSF=A’cr’’lf’ or
>add/LSF=NO_FAULT’cr’’lf’

Where: A=LNA Status, 0=OK, 1=FLT

X= Stored Fault Locations (0 to 9)

LSF= (message ok)
LSF? (received ok, but invalid arguments
found)
LSF* (message ok, but not permitted in
current mode)

LSF?

AGC Stored
Faults

n.a.

3 bytes

Query only.
<add/ASF?X’cr’
>add/ASF=ABC’cr’’lf’ or
>add/ASF=NO_FAULT’cr’’lf’

Where: A=Loop Convergence, 0=OK, 1=FLT

B=Excessive Input Power (EIP), 0=OK, 1=FLT
C=Insufficient Input Power (IIP), 0=OK, 1=FLT
X=Stored Fault Locations (0 to 9)

ASF= (message ok)
ASF? (received ok, but invalid arguments
found)
ASF* (message ok, but not permitted in
current mode)

ASF?

Common
Equipment
Stored Faults

n.a.

4 bytes

Query only.
<add/CSF?X’cr’
>add/CSF=ABCD’cr’’lf’ or
>add/CSF=NO_FAULT’cr’’lf’

Where: A=–7V PS Status, 0=OK, 1=FLT

B=+7V PS Status, 0=OK, 1=FLT
C=+12V PS Status, 0=OK, 1=FLT
D=+17V PS Status, 0=OK, 1=FLT
X=Stored Fault Locations (0 to 9)

CSF= (message ok)
CSF? (received ok, but invalid arguments
found)
CSF* (message ok, but not permitted in
current mode)

CSF?

Clear Stored
Faults

CSA= None

Command

only.

<add/CSA=’cr’
>add/CSA=’cr’’lf’

CSA= (message ok)
CSA? (received ok, but invalid arguments
found)
CSA* (message ok, but not permitted in
current mode)

n.a.