3 faults, 1 faults: current, 2 faults: stored – Comtech EF Data LBC-4000 User Manual

Page 70

Advertising
background image

LBC-4000 L-Band Up/Down Converter System with Ethernet

Revision 2

Front Panel Operation

MN-LBC4000A

5–14

5.2.3

FAULTS

CURRENT STORED

 
Use the [][] arrow keys to select the CURRENT or STORED faults, and then press [ENT]. 

5.2.3.1 FAULTS: CURRENT

Use the[][] arrow keys to scroll between and view the available lists of current faults.  
 
For all read‐only Fault displays, press [ENT] or [CLR] to return to the previous menu. 
 
The following table identifies each read‐only display available from the FAULTS: CURRENT menu 
branch, including a sample screen and a functional description of the display: 
 

Submenu

Example

Description

Conv-A

Faults: Conv-A
iflo=OK rflo=OK temp=OK

For Converter Unit A or B: The faults
for the selected Up/Downconverter
IDU are shown, where:

iLO = IF Lock Fault
rLO = RF Lock Fault
Tp = Oper Temp (°C) Fault

Conv-B

Faults: Conv-B
iflo=OK rflo=OK temp=OK

PwrSupA

Monitor PS A: 12V=OK
8V=OK 5V=OK

The 12V, 8V, and 5V faults for the
selected power supply are shown.

PwrSupB

Monitor PS B: 12V=OK
8V=OK 5V=OK

Ext RefOsc

Faults: Ext Ref
Ext Ref = FT

The external reference oscillator fault
menu

5.2.3.2 FAULTS: STORED

VIEW CLEAR-ALL

 
Use the [][] arrow keys to select VIEW or CLEAR‐ALL, and then press [ENT]. 

FAULTS: STORED

Æ VIEW

Fault No. 06 10:28:53
OK-IFLO_A 08/10/04

 

Advertising