Maintenance &

4-5

LED

Function

Name

Operation

PWR

Controller has power

Always On

RUN

Controller is running

Flashes approximately once per second

LGHT

Light Detector Input

Light Level=Flash Rate

TEMP

Temp Sensor Input

Temperature=Flash Rate

RX2

Data In – COM1

On while Communicating

RX2

Data In – COM2

On while Communicating


The W1 and W2 jumpers
on the controller board
must be ON for modem
communication and OFF

r

RS422 and fiber optic.

switches are on the

addresses.

fo all others: RS232,


Before this display can be
run in a sign network it
must have an address. The
display address can be set
using the DIP switches on
the MDC board. The

underside of the MDC
board near TB7 of the controller board. The following table lists the switch setting for various

Figure 16: Controller Board

Address Switch

Switch

Switch

Switch

Switch

Switch

Sw

8

7

6

5

4

3

itch

2

Switch

1

1

OFF OFF OFF OFF OFF OFF OFF ON

2

OFF OFF OFF OFF OFF OFF ON OFF

3

OFF OFF OFF OFF OFF OFF ON ON

4

OFF OFF OFF OFF OFF ON OFF OFF

5

OFF OFF OFF ON OFF ON

OFF OFF

6

OFF OFF OFF OFF OFF ON ON OFF

7

OFF OFF OFF OFF OFF ON ON ON

8

OFF OFF OFF OFF ON OFF OFF OFF

9

OFF OFF OFF OFF ON OFF OFF ON

10 OFF OFF OFF OFF ON OFF ON OFF

11 OFF OFF OFF OFF ON OFF ON ON

... ... ... ... ... ... ... ... ...

127 OFF

ON ON ON ON ON ON ON

If ever the need arises to replace the Venus 1500 display controller, make sure the DIP switches
on the MDC are set for the same address as the old controller.

The controller board is one functional unit and must be replaced as a single device.