Appendix B:

Signal Converter

The following table gives the typical state of the signal converter when the LEDs are either on or off.
Refer to Figure 17 for an illustration of the signal converters and the locations of the various
components.

LED Indicators

Typical States

ON

Signal Converter (SC) is receiving power.
SC is not receiving power.

PWR

OFF

Internal 1 AMP Fuse is bad.
SC is not connected to a serial port.

ON Steady

(If connected to serial port) Serial port or serial
cable may be bad.

OFF Steady

Normal state, SC is not transmitting data.

TX

Brief Flicker

SC is transmitting data.

ON Steady

connected to display out or terminated

Field cabling between SC and display is bad,

incorrectly.

RX

OFF Steady

Normal state, SC is not receiving data.

Brief Flicker

SC is receiving data.


0A-1127-0237 – Wire

The following tables list the jack pin-outs for a wire signal converter.

J2 & J3 - RJ/11

J4 & J5 – Phoenix

PIN OPERATION

PIN

OPERATION

1 GND

1 GND

2

TX-N (out)

2

RX-P (in)

3

TX-P (out)

3

RX-N (in)

4

RX-N (in)

4

TX-P (out)

5

RX-P (in)

5

TX-N (out)

6 GND

6 GND

Figure 17: Signal Converters

J1 25 Pin DB-F

PIN OPERATION

2 TX-P

(out)

3 RX-P

(in)

7 GND

Appendix B: Signal Converter

B-1