Installation - rds instruments – Digi-Star ICP 300 User Manual

Page 7

Advertising
background image

ICP 300 IN-CAB PRINTER

7

3.

Installation - RDS Instruments

3.1

Connection - RDS 'Wizard','G-Wiz', 'G-CAN', 'ISOCAN'

(Printer cable Pt No. S/CB/167-4-005)

These instruments all utilise variants of the 'Terminator' junction box for
RS232 serial connections.

A 4-way IDC header is the standard connection for the ICP300 printer (fig. 5).

IDC Connections:

Pin

Wire Colour

Function

1

White

+V Supply (10-35V)

2

Red

CST (from printer

3

Green

Rx (To printer)

4

Blue

ground

1. Plug the printer cable (RJ-12) into the back of the printer.

2. Plug the printer cable in the terminal box as shown (using a cable-tie for

strain relief).

Figure 5